• PDD500A101 3BHE037649R0101 3BHE037650P201 (3)_副本

PDD500A101 3BHE037649R0101 3BHE037650P201 | ABB | Slave Register Address

¥8,855.00

Module Number: PDD500A101 3BHE037649R0101 3BHE037650P201

Product status:  Discontinued

Delivery time:  In stock

Sales country: All over the world

Product situation: Brandnew , one year warranty

Contact me: Sauldcsplc@gmail.com  +8613822101417   SIMON

Have a good day! Thanks for watching my website!

 

 

Category: Tags: , ,

Description

PDD500A101 3BHE037649R0101 3BHE037650P201 | ABB | Slave Register Address

  1. .Many products are not yet on the shelves please contact us for more products
  2. .If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation
  3. .We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible

 

As shown in the above figure, on this interface, PDD500A101  is possible to collect and monitor Modbus slave station flow meter data. According to the Modbus slave register address and I/O data mapping relationship set in the PMG-123 and STEP7 configuration interfaces, the two words corresponding to the PLC input mapping addresses PIW256 and PIW258 are the “first sampling pressure value” of the flow meter with Modbus slave address 1, corresponding to the displayed 1.000Kpa of the flow meter; The two words corresponding to the PLC input mapping addresses PIW260 and PIW262 are the “second sampling temperature value” of the flow meter with Modbus slave address 1;

The two PDD500A101  corresponding to the PLC input mapping addresses PIW264 and PIW266 are the “third sampling pressure value” of the flow meter with Modbus slave address 1, which is not displayed on the instrument display interface; The two words corresponding to the PLC input mapping addresses PIW268 and PIW270 are the “instantaneous values” of the flow meter with Modbus slave address 1, and so on. The Modbus slave register address data corresponding to the Modbus related commands configured in PMG-123 can be collected and monitored in the I/O mapping area address corresponding to the PLC.

 

Mailbox:sauldcsplc@gmail.com |PDD500A101 3BHE037649R0101 3BHE037650P201
www.abbgedcs.com | Qiming Industrial Control | Simon +86 13822101417

Reviews

There are no reviews yet.

Be the first to review “PDD500A101 3BHE037649R0101 3BHE037650P201 | ABB | Slave Register Address”

Your email address will not be published. Required fields are marked *